Cement Bulk Loader: Malfunction Analysis and Handling Guide

1. Introduction and Working Principle

The cement bulk loader is essential equipment at cement plants and mixing stations. Its purpose is to load bulk cement quickly and cleanly into tanker trucks. The goal is efficient loading and effective dust control.

Here is how it works:

  1. Positioning and Sealing: The operator lowers the loader’s discharge spout (usually with a flexible sleeve). The spout connects tightly to the truck’s inlet. This creates a closed transfer path.

  2. System Start-Up: The dust collection system starts first. Then, the air supply system and discharge valve activate. The dust collector creates a slight vacuum at the loading point. This prevents dust from escaping.

  3. Material Transfer: Air from the Roots blower makes the cement fluid inside the silo. The cement then flows by gravity through the open valve and into the truck.

  4. Full Detection and Shutdown: A level probe or scale signals when the truck is full. The system then automatically closes the discharge valve and raises the spout. The loading cycle is complete.

Understanding this process is key to diagnosing the malfunctions below.

 

2. Common Malfunctions and Handling Methods

Malfunction 1: Poor Dust Collection

  • Symptom: Excessive dust escapes during loading.

  • Analysis: This failure affects the core dust control function. It usually involves a seal failure or airflow problem.

  • Action Steps:

    • First, check the program sequence. Ensure the dust collector fan and its inlet valve start at the same time as the loading cycle. Check the PLC settings or timers.

    • Next, inspect all seals. Pay special attention to the flexible lift sleeve (bellows). Look for wear or tears. Replace it immediately if damaged, as this is a main dust leak path.

    • Finally, check the dust collection system itself. See if the filter bags are clogged. Verify that the pulse cleaning system works. Also, check the ducts for leaks or blockages.

Malfunction 2: Lift Motor Does Not Move

  • Symptom: The motor does not respond to lift/lower commands. The spout stays in place.

  • Analysis: This problem can be electrical, related to overload, or purely mechanical.

  • Action Steps: (Check from simple to complex)

    • Start with the electrical system. Check the motor power supply (3-phase voltage). Inspect the control circuit (buttons, contactors, relays). Also, test the safety limit switches (top and bottom).

    • Then, check for a mechanical overload. See if the spout is jammed by built-up material or is stuck against the truck. Clear any material and ensure the path is clear.

    • Finally, inspect the mechanical parts. Check the steel wire rope/chain for derailment, jamming, or breakage. Also, examine the gear reducer, pulleys, and bearings. Straighten, lubricate, or replace the wire rope as needed.

Malfunction 3: No Material Discharge During Loading

  • Symptom: Cement does not flow out after the loader is in position.

  • Analysis: This indicates a break in the material flow path. Follow the path backwards from the final actuator.

  • Action Steps:

    • First, check the final actuator. Confirm the discharge pneumatic/electric valve opens fully when signaled. Inspect the air circuit (air pressure, hoses, fittings) and the main control valve (solenoid valve).

    • Then, check the material condition. Look for clumped cement inside the silo. Also, check if the loader inlet or outlet is blocked by debris or clumps. Clear any blockage. Contact the silo operator if needed.

    • Finally, check the power source. Ensure the Roots blower runs normally. It provides the critical air for material fluidization. Check the blower’s motor, belts, coupling, and related electrical components.

3. Maintenance and Safety Notes

  • Perform regular maintenance. Follow a schedule. Regularly check the lift wire rope for wear. Lubricate all moving parts. Clean sensors (like the level probe). Test the air system for leaks.

  • Always put safety first. Before any repair, always lock out and tag out the power source. Also, release any leftover air pressure from the lines. Never use your hands to clear a blockage; always use the correct tools.

  • Keep detailed records. Write down every malfunction: the symptom, the cause, and the fix. This helps identify recurring issues. Use this information to plan part replacements or technical upgrades. This will reduce downtime in the future.